Emerson 1F85 0471 Thermostat User Manual

Home

href="
BLUE Universal Thermostats  
4 square inch display  
Single Stage / Multi-Stage / Heat Pump Applications  
Non-Programmable, Programmable 5/1/1, 5/2 Day or 0 Programmable  
Hardwired or Battery Powered  
ACCURACY  
COMFORT YOU  
CAN COUNT ON  
Includes Wall Plate F61-2634  
PROGRAMMABLE MODELS  
1
1
F85-0471 3/2  
F85CA-0471 3/2  
Comfort-Alert Model  
with Active Protection for Systems with  
ComfortAlert Compressor Diagnostics  
Programmable  
1
F85-0422 2/2  
NON-PROGRAMMABLE MODELS  
1
1
F83-0471 3/2  
F83-0422 2/2  
Quick One-Button Programming  
Non-Programmable  
Exclusive Cool Savings  
Exclusive Battery Power Monitor  
5
-Year Warranty  
Millivolt and Hydonic Zone Valve Compatible  
href="
1
F85-0471/1F85CA-0471/1F85-0422  
5
/1/1, 5/2 Day or 0 Programmable  
1
F83-0471/1F83-0422  
Non-Programmable  
BLUE Universal Thermostats  
For Single Stage, Multi-Stage and Heat Pump Systems • 5/1/1, 5/2 Day, 0 Programmable or Non-Programmable • Hardwired or Battery Powered  
Exclusive 4" Blue Features  
Large, 4-square-inch Blue display  
with easy-to-see characters  
Programming  
Comfort & Convenience  
Performance  
Choice of 5/1/1 day programmable,  
5/2 day or non-programmable  
Optional minimum and maximum  
temperature configurable  
Dual-Powered…choice of  
battery-powered or hardwired,  
for all applications  
(
1F85-0471, 1F85CA-0471, 1F85-0422)  
Active protection for systems with  
ComfortAlert CA2 module compressor  
diagnostics (1F85CA-0471)  
Permanent program retention  
during power loss  
4
time and 4 temperature settings  
Selectable Energy  
Management Recovery  
(1F85-0471, 1F85CA-0471, 1F85-0422)  
per program (heat & cool)  
Indefinite setpoint Hold  
Quick one-button programming  
Energy savings up to 33%  
Air filter change indicator  
(optional)  
(
See Automatic Schedule section in  
®
Meets ENERGY STAR specifications  
Patented pre-programmed  
software simplifies time and  
temperature programming  
installation instructions)  
(
1F85-0471, 1F85CA-0471, 1F85-0422)  
Simple “set-up” menu to  
activate optional features  
Configures as manual heat/cool,  
auto changeover, heat only  
or cool only  
Meets California Building Code,  
Title 24 (1F85-0471, 1F85CA-0471,  
Display  
Temporary temperature  
1
F85-0422)  
Large LCD with improved  
contrast for easier reading  
override two-hour minimum  
or until next program period  
(1F85-0471, 1F85CA-0471, 1F85-0422)  
Exclusive Cool Savings feature  
Fast (FA) or slow (SL) heating  
cycle anticipation  
saves energy during peak A/C  
demand periods  
Lighted display for easier  
low-light viewing  
Easy-to-wire terminal block  
Compressor lockout protection  
Millivolt compatible  
Hydronic 2 or 3 wire zone valve  
applications  
Soft-touch keypad  
Display temperature  
recalibration (+/- 4°)  
Exclusive battery power monitor  
5-year warranty  
Electric heat option  
Terminal Designations  
RC  
RH  
C
G
W/E W2  
Y
Y2 O/B  
6
L
Dimensions  
Thermal Specifications  
Accessories  
5
.1"W x 3 .9"H x 1.2"D  
Setpoint Temperature Range:  
Wall Plate F61-2634 (6.5"W x 5"H)  
for 80 Series Blue  
4
5° to 90° F (7° to 32° C)  
Electrical Specifications  
(Included with 1F85-0471, 1F85CA-0471,  
8
0 Series Blue Rated  
1
F85-0422, 1F83-0471, 1F83-0422)  
Rating  
Differential: 0.4° to 1.7° F  
with adjustable anticipation  
0
0
2
to 30 VAC, 50/60 Hz or DC  
Thermostat Guard F29-0231  
.05 to 1.5 Amps (load per terminal)  
Operating Ambient Temperature:  
(For additional guard options refer to White-Rodgers  
catalog at www.white-rodgers.com)  
3
2° to 105° F (0° to 40° C)  
Operating Humidity Range:  
0% non-condensing maximum  
Shipping Temperature Range:  
4° to 150° F (-20° to 65° C)  
.5 Amps maximum load  
(
all terminals combined)  
For Additional Information  
9
Standard Systems  
Gas, oil, electric  
Visit www.white-rodgers.com  
-
Single Stage/Heat Pump/Multi-Stage  
Millivolt Systems  
2
or 3 wire hydronic zone valve  
Single Multi- Heat  
Stage Stage Pump  
Programs  
Model  
Applications  
Selectable Performance Features  
Comfort and Convenience Features  
Stages  
Heat/Cool  
by System  
Program  
Options  
Model  
Number  
1
1
1
1
1
/1 2/2 3/2 5+2,5+1+1,Ø 1F85-0471  
B,H  
B,H  
B,H  
B,H  
B,H  
/1 2/2 3/2 5+2,5+1+1,Ø 1F85CA-0471  
/1 2/2 2/2 5+2,5+1+1,Ø 1F85-0422  
/1 2/2 3/2  
/1 2/2 2/2  
Ø
Ø
1F83-0471  
1F83-0422  
B =Battery, H =Hardwired, PA =Power Stealing Assist *** Optional Continuous Display Light w/Hardwire Connection  Only One (1) Remote Sensor May Be Used – Either Indoor or Outdoor; or Logic Program and Indoor Remote Sensor  
St. Louis, Missouri Markham, Ontario  
3
14-553-3600 905-201-4701  
www.white-rodgers.com  
The Emerson logo is a trademark and  
a service mark of Emerson Electric Co.  
WR-7255-2  

Bryant T6 PRH A Thermostat User Manual

Honeywell T8775A,C Thermostat User Manual

Carrier 33CS2PPRH 01 Thermostat User Manual

Aube TH148LE Thermostat User Manual

Carrier TM004 014 Thermostat User Manual

White Rodgers 1F97 1277 Thermostat User Manual

Honeywell T8602 Thermostat User Manual

Lux Products T40 1143 Thermostat User Manual

Aprilaire 8555 Thermostat User Manual

Honeywell T8034C Thermostat User Manual