Emerson 1F95 1280 Thermostat User Manual

Home

href="
BLUE COMMERCIAL4/2  
Single Stage / Multi-Stage / Heat Pump  
Programmable (7 Day, 5/1/1 Day) or Non-Programmable  
Economizer / Damper Control Output  
ACCURACY  
OPTIMUM COMFORT  
AND PERFORMANCE  
Hardwired or Battery Powered with Optional Power Stealing Assist  
1
F95-1280  
Universal Application  
Heat / 2 Cool  
4
12-square-inch touchscreen display  
Keypad lockout – total or partial  
Dual fuel with outdoor sensor (F145-1378)  
or by logic program  
1
F95-0680  
Universal Application  
4
Heat / 2 Cool  
6-square-inch display  
Lock feature secures thermostat  
to subbase, reduces tampering  
Dual fuel with outdoor  
sensor (F145-1378)  
5-Year Warranty  
Commercial Control. Customer Comfort.  
®
®
Emerson Big Blue Commercial and Emerson Blue Commercial Thermostats from White-Rodgers are designed specifically  
for commercial applications, delivering a new level of comfort, control and security to your customers.  
Exclusive Blue Commercial Features  
Standard Blue Features  
Pre-occupancy purge and/or programmable fan  
Economizer/damper control output  
• Limited temperature range – energy-saving feature  
• Large, 12-square-inch or 6-square-inch display with backlight  
Remote sensing indoor and at the thermostat  
Keypad lockout – total or partial  
• Exclusive Cool Savings feature saves energy during  
peak A/C demand periods  
Automatic daylight savings option  
href="
BLUE COMMERCIAL4/2  
1F95-1280 / 1F95-0680  
Universal Application  
4
Heat / 2 Cool  
Single Stage / Multi-Stage / Heat Pump  
Programming  
Universal – installer selectable system applications  
Choice of 7 day, 5/1/1 day programmable or  
non-programmable (installer selectable)  
Performance  
Choice of battery-powered with optional power  
stealing assist or hardwired with battery backup  
Selectable Energy Management Recovery  
Meets California Building Code, Title 24  
Fast (FA) or slow (SL) heating cycle anticipation  
Exclusive “Call for Service” diagnostic indicator  
Compressor lockout protection  
Flexible temporary temperature override will  
override program for four (default) hours –  
1
F95-1280  
Temporary temperature override will  
override program for two hours –  
1F95-0680  
Auto heat/cool changeover option –  
automatically switches between heating  
and cooling programs  
Heating and cooling, heating only or cooling  
only configuration (installer selectable)  
Setpoint temperature “limited range”  
capable  
2
time and 2 temperature settings  
(
1 setback) – 1F95-1280  
Choice of 4 time and 4 temperature settings per  
program (2 setbacks) or 2 time and 2 temperature  
settings (1 setback) – 1F95-0680  
Energy savings up to 33%  
Patented pre-programmed schedule simplifies time  
and temperature programming  
Millivolt compatible  
Electric heat option  
Comfort & Convenience  
Intuitive menu-driven setup, programming and  
operation, with audio prompt to confirm entries  
Permanent program retention during power loss  
Indefinite setpoint Hold or  
temporary temperature override  
Enhanced locking security reduces  
tampering – 1F95-0680  
Furnace filter change reminder  
Display  
Large, 12-square-inch touchscreen display – 1F95-1280  
Large, 6-square-inch display – 1F95-0680  
Blue, lighted display for easier low-light viewing  
Larger, easy-to-read character size  
Large keys for easy operation  
Maintains room temperature to within  
+
/- 1˚F  
Room temperature display can be  
recalibrated up to +/- 4˚F  
Terminal Designations* Terminal Block Wire Connection – 1F95-1280  
Terminal Block Wire Connection – 1F95-0680  
RC RH  
W/E W2  
Y2  
RC RH  
C
W/E W2  
Y
Y2  
G
O/B  
6
L
A1  
+
S
C
Y
G
O/B A1  
6
L
+
S
*See installation instructions or www.white-rodgers.com for terminal descriptions  
Dimensions  
Electrical Specifications  
Rating  
Accessories  
4
.6"H x 5.9"W x 1.2"D – 1F95-1280  
Indoor Remote Sensor  
F145-1328  
Outdoor Remote Sensor  
F145-1378  
Battery Power: mV to 30 VAC, NEC Class II,  
4
.2"H x 6.4"W x 1.7"D – 1F95-0680  
50/60 Hz or DC  
Thermal Specifications  
Input Hardwire: 20 to 30 VAC  
1.5 Amps (load per terminal)  
Setpoint Temperature Range:  
Thermostat Guards  
Clear – F29-0198  
4
5˚ to 99˚F (7˚ to 37˚C)  
2
.5 Amps maximum load (all terminals combined)  
Metal – F29-0220 (solid base)  
Rated Differential:  
Heat 0.6˚F; Cool 1.2˚F  
Standard Systems  
Single Stage gas, oil, electric  
Wallplates  
F61-2600 (8.1"W x 5.4H")  
F61-2634 (6.5"W x 5"H)  
Operating Ambient Temperature:  
Single Stage heat pump  
Millivolt systems  
3
2˚ to 105˚F (0˚ to 41˚C)  
Operating Humidity Range:  
0% non-condensing maximum  
Shipping Temperature Range:  
40˚ to 150˚F (-40˚ to 65˚C)  
Multi-Stage gas, oil, electric  
Multi-Stage heat pump  
For Additional Information  
Visit www.white-rodgers.com  
9
-
Single Multi- Heat  
Stage Stage Pump  
Programs Applications  
Selectable Performance Features  
Comfort and Convenience Features  
Stages  
Heat/Cool  
by System for  
F95-1280 and  
Program  
Options  
1
1F95-0680  
1
/1 2/2 4/2 7, 5+1+1, Ø  
✓ ✓ H,B/PA  ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓  
B =Battery, H =Hardwired, PA =Power Stealing Assist *Outdoor Sensor F145-1378 Required for 1F95-0680 ***Optional Continuous Display Light w/Hardwire Connection  
Only One (1) Remote Sensor May Be Used – Either Indoor or Outdoor; or Logic Program and Indoor Remote Sensor  
St. Louis, Missouri Markham, Ontario  
3
14-553-3600 905-948-3411  
www.white-rodgers.com  
www.emerson.com  
The Emerson logo is a trademark and  
a service mark of Emerson Electric Co.  
WR-4495A  

Honeywell RTH2510B1000E1 Thermostat User Manual

White Rodgers 37 6753B Thermostat User Manual

Honeywell Q674E Thermostat User Manual

Bryant T1 NHP Thermostat User Manual

Hunter Fan T200 Thermostat User Manual8659

Honeywell TRV15AHC Thermostat User Manual

Carrier P274 0200 C Thermostat User Manual

White Rodgers 1E50N 303 Thermostat User Manual

Honeywell T8602A C Thermostat User Manual

Bryant T874 Thermostat User Manual